LARYNGEAL STROBOSCOPY PDF

In , Kay Elemetrics (now KayPENTAX) introduced laryngeal stroboscopy systems that precisely controlled the triggering of light sources so that only one. Laryngeal stroboscopy: This examination is a specialized viewing of vocal fold vibration. Laryngeal stroboscopy involves controlled high-speed flashes of light. Video laryngeal stroboscopy (VLS) is a procedure done to evaluate the motion of the vocal cords. It allows the physician to tell the difference between different.

Author: Shakalkis Doramar
Country: Portugal
Language: English (Spanish)
Genre: Sex
Published (Last): 24 May 2018
Pages: 253
PDF File Size: 15.50 Mb
ePub File Size: 9.48 Mb
ISBN: 974-6-24838-374-6
Downloads: 18745
Price: Free* [*Free Regsitration Required]
Uploader: Goltirn

Application of high-speed imaging.

The images generated are transmitted as a video, which can be recorded and viewed repeatedly. The therapist can then assess various parameters to help plan effective, individualized treatment to improve the patient’s ability to produce voice. Update on pediatric voice and airway disorders: In a study utilizing HSV of glottic cancer patients, variations in levels of acoustic jitter and shimmer were found to be unrelated to average measures of asymmetry; instead, a significant amount of the variation in acoustic jitter was accounted for by the standard deviation in the symmetry of phase and amplitude across the vibratory cycles [ 18 ].

Specifically, stroboscopy evaluates several parameters of the vibration cycle, including fundamental frequency, periodicity, closure of the glottis, and vocal fold symmetry.

One way to answer this question is to ask judges to rate laryngeal features from HSV and videostroboscopy recordings of sustained phonation and compare the ability of each modality to reliably reveal certain features. Verified Doctors Our goal is to give you access to powerful and credible information that is not available anywhere else.

Advantages These technologies provide valuable practitioner and patient information. The free edges layrngeal the vocal folds appear as a blur. This examination allows for viewing the voice box in action. If you have concerns after your child has had a flexible nasopharyngoscopy, please contact the ENT office or seek medical attention. The interpretation of stroboscopy results is likewise dependent on the clinician.

Stroboscopy systems and components. A detailed discussion of the interaction among strobe rate, video camera rate, and phonatory fundamental frequency is provided in Hillman and Mehta [ 10 ]. Hoarseness dysphonia Otolaryngol Head Neck Surg. The Laryngograph Laryngeal Strobe system with 70 degree rigid Machida endoscope strobboscopy attached digital camera head.

  CABRONITA PICKGUARD PDF

Understanding Laryngeal Stroboscopy

Possible Risks and Complications Complications are rare with stroboscopy with most problems encountered related to patient discomfort during the procedure.

By taking multiple snapshots at different phases of the vibratory cycle it is possible to see details of the change in shape of pliable surface of the vocal folds i. Summary Laryngeal videostroboscopy continues to be the modality of choice for imaging vocal fold vibration, but technological advancements and HSV research findings are driving increased interest in the clinical adoption of HSV to complement videostroboscopic assessment. This study offers evidence that visual stroboscopic assessment could be reduced to a small number of parameters stroboscoppy potentially increase efficiency in rating stroboscopic recordings.

The two categorically scaled parameters of vertical level and glottal closure were judged so unreliably that it was suggested that their assessment might hold little information [ 15 ].

The limitation of stroboscopy is that the procedure is operator-dependent. Typically, a microphone detects the frequency of vocal fold strobosscopy, which triggers the light source, producing the intermittent flashes of light.

Current role of stroboscopy in laryngeal imaging

This can be paryngeal by analysing one three types of signal: Advisory Note Patient education material presented here does not substitute for medical consultation or examination, nor is this material intended to provide advice on the medical treatment appropriate to any specific circumstances.

See other articles in PMC that cite the published article. A case study also points to the need for HSV-based imaging to describe more detailed vocal fold tissue larngeal during pre- and post-therapy assessment [ 22 ]. Flexible laryngoscopy provides a magnified view of the voice box while the patient produces sound speaking, singing, etc.

Video Laryngeal Stroboscopy

Stroboscopy is a procedure performed to evaluate the vibration of larynheal vocal cords. The child will be asked to perform several voice exercises while the ,aryngeal is in place.

Are you interested in learning more about a video laryngeal stroboscopy? Asia’s Largest Physician Network DocDoc has Asia’s largest healthcare physician network with 23, doctors, clinics and 55 hospitals from various specialties throughout the region.

  DISPUESTA A TODO ANNA DEPALO PDF

If each image is shown one after the other as a movie changes in the a mucosal wave can be seen Figure 2: Ann Otol Rhinol Laryngol.

Specific details, such as the mucosal laryngesl and the changes in the shape of the vocal folds, can be examined more accurately with stroboscopy. Contributor Information Daryush D. The movement of the vocal folds is fast but the technology of stroboscopy enables its evaluation at various srtoboscopy of the vibratory cycle, in real-time and in slow motion. This book chapter details the principles behind stroboscopic imaging and its application to video-based laryngeal imaging.

Video Laryngeal Stroboscopy

Why would my child need a video laryngeal stroboscopy? Laryngeal videostroboscopy layrngeal to be the imaging modality of choice by voice clinicians due to its historical use and ability to efficiently capture many salient vocal fold vibratory characteristics.

The procedure is done with the child awake and in the sitting position.

State of the art laryngeal imaging: The slight time delay means that the vocal folds are illuminated at a slightly later point in the vibratory cycle Figure 3.

The reasons for this are:. High-speed videoendoscopy HSV judgments have been shown to be more sensitive than stroboscopy for evaluating laryngesl fold phase asymmetry, pointing to the potential of complementing stroboscopy with alternative imaging modalities in hybrid systems.

A multi-media, computer-based method for stroboscopy rating stroboscoly. The authors address a fundamental issue— interrater reliability— that plagues any perceptual rating scales.

The head is extended and neck flexed. Regardless of method, the flash or shutter durations are sufficiently short to prevent motion stroboscppy artifacts in images that may arise due to rapid vocal fold tissue movements that can approach velocities of one meter per second [ 11 ].

Modified version of Figure